0 |
0 |
23413 |
answers |
votes |
views |
Hi,
I wanna Brukers TopSpin/XWIN-NMR to log the start and end
times of every experiment.
With this information I can ...
Posted:
oxy
31
Aug 28 '19 at 01:42
0 |
0 |
5k |
answers |
votes |
views |
Hi there,
I am looking for the pulse program for the PENDANT experiment, for a Bruker Avance III spectrometer, has anyon...
0 |
0 |
11521 |
answers |
votes |
views |
Hello everyone,
I had to change a BVT3300 module in a Bruker Avance 300 console today. Everytihing went fine and the mo...
Updated:
gael58
1
Feb 22 '18 at 07:45
0 |
0 |
8k |
answers |
votes |
views |
Hi,All,
I wonder if somebody can tell me why in these two experiments( also hbha(co)nh,I think) in Bruker(not sure if yo...
Updated:
blue
1
Feb 28 '17 at 08:37
2 |
0 |
3k |
answers |
votes |
views |
We have been trying to get a 2D H-F experiment to work using the X 100 W amplifier on our Bruker NMR, but can't get it t...
0 |
0 |
9k |
answers |
votes |
views |
Hi all,
My question is about the Multiple Display (.md) function on TopSpin (Bruker AVIII).
I did some 'popt' ( paramete...
Posted:
TiagoB1
1
Nov 11 '15 at 03:40
0 |
0 |
1k |
answers |
votes |
views |
I am running Paravision 4.0 from Topsin 1.5 with one receiver coil. I would like to increase the PPI acceleration factor...
Posted:
adam
1
Jul 21 '15 at 05:18
1 |
0 |
5k |
answers |
votes |
views |
Hi, I'm having a problem with topshim on Bruker AV 500 using topspin 2.1. it finishes with error (topshim: FieldMap - no...
1 |
0 |
3k |
answers |
votes |
views |
Hi all,
I'm having trouble reading the 2dseq file for a scan I ran. It should contain 2 slices of 66x50 voxels, repeate...
1 |
0 |
6k |
answers |
votes |
views |
Hello,
I was wondering if there was a waterLOGSY sequence among the bruker sequences. If not, could someone tell me whe...
2 |
0 |
9k |
answers |
votes |
views |
HELLO all nmr wikier,I am facing problem in runing topshim on bruker 500Mhz using topspin 2.1 it finishes with error (fi...
5 |
0 |
7k |
answers |
votes |
views |
Hello people,
Does anyone know of any free NMR software (no trials, I can't stand it anymore) that is robust enough to ...
1 |
0 |
3k |
answers |
votes |
views |
Hi , Does any one know how to set up the zgesfpgp 1d experiment (flipback water gate) on Bruker. I am looking for p29 du...
0 |
0 |
1k |
answers |
votes |
views |
Hello people,
It's all in the title.
...
2 |
0 |
7k |
answers |
votes |
views |
Hi ,
is there a way of predicting aquisition time needed depending on sample concentration in order to get a decent spe...
2 |
0 |
6k |
answers |
votes |
views |
Hi,
I am trying to run a wet sequence but I'm having trouble getting good results on a sample with 90:10 water:methanol...
3 |
0 |
14163 |
answers |
votes |
views |
Hi,
I was wondering why so many pulse programs use dummy scans. Correct me if I'm wrong but I think dummy scans are supp...
1 |
0 |
3k |
answers |
votes |
views |
hi there.
I want to establish an au with the following content:
I want to measure 1H and 31P make ssleep (userdefined)...
5 |
0 |
10011 |
answers |
votes |
views |
Hello, could you tell me which HSQC and E-HSQC program are recommendable ?
These are Bruker HSQC pulse programs:
hsqcp...
1 |
0 |
8k |
answers |
votes |
views |
Hello all,
I have several 2D and 3D data sets acquired using Bruker spectrometers in the standard uniform sampling fash...
Updated:
ChemMJW
99
Aug 23 '14 at 20:43
4 |
0 |
25449 |
answers |
votes |
views |
Greetings,
I want to ask for some advice in matter of 15N hard pulse calibration on Bruker machines.
I'm working on Avan...
3 |
0 |
7k |
answers |
votes |
views |
Hi all, I have been running TopSpin 2.1 on my Windows 7 32-bit OS for the last few years and now am getting this annoyin...
1 |
0 |
6k |
answers |
votes |
views |
Greetings,
I've some annoying issue with Topspin and deconvolution. No matter what I'm trying to do, border peaks are a...
3 |
0 |
7k |
answers |
votes |
views |
Greetings,
this is my first question in this wiki :)
I wonder if there's possibility to obtain full homo decoupled spe...
0 |
0 |
4k |
answers |
votes |
views |
Hello,
I can't get results, as unknown error occures data/results.csv
I'd restarted spectrometr several time, but the s...
1 |
0 |
71905 |
answers |
votes |
views |
Hi all, I have a small question on how to aquired a complete signal in BRUKER AVIII.
I want to create a multi pulse sequ...
1 |
0 |
3k |
answers |
votes |
views |
Hi all,
I have a 2D Bruker dataset that took a while to acquire, so I'd rather not simply repeat it. However, it seems...
1 |
0 |
3k |
answers |
votes |
views |
I was running a 3D 15N edit NOESY (on a Bruker 600) and it was inadvertently stopped. I would like to restart the experi...
1 |
0 |
8k |
answers |
votes |
views |
Hi, I am unable to activate our lift on our avance III 400 NMR from BruKer The message is emergency air lift activated....
1 |
0 |
4k |
answers |
votes |
views |
Hello all,
Our daily check sample for the Minispec mq40 has been decreased in volume due to probably evaporation!!
An...
1 |
1 |
9k |
answers |
votes |
views |
I had just finished refilling the nitrogen and powering up the NMR after the holiday shutdown and went through the norma...
0 |
0 |
7k |
answers |
votes |
views |
Hi,
I'm looking for a pulse program suitable for Bruker Avance llI (topspin 2.1) which is 2D homonuclear correlation wit...
2 |
1 |
5k |
answers |
votes |
views |
Hi everyone
I would like to write some code to read in spectra that were processed using TopSpin (Bruker), but so far I...
2 |
0 |
11841 |
answers |
votes |
views |
I need to set up 2H NMR on a Bruker 600 MHz BBO probe for the first time. Can anyone give me a set of instructions?
Do ...
3 |
1 |
7k |
answers |
votes |
views |
I've received a loaner probe from Bruker while ours is being repaired but I'm not getting any timely response on instruc...
1 |
0 |
4k |
answers |
votes |
views |
Would anyone have a recent generation Bruker HNCO (or similar) data set that they would be willing to share with me for ...
3 |
0 |
10715 |
answers |
votes |
views |
I am working on a MAS solid-state NMR Bruker spectrometer using Topspin. Is anyone familiar with a macro for running sev...
1 |
0 |
9k |
answers |
votes |
views |
HI nmr wikier
I want to test bruker nmr spectometer bsms unit on board level including all boards.
How to run the test f...
2 |
1 |
14827 |
answers |
votes |
views |
Hi All,
This may be a daft question, but how do I go about identifying the probe in our NMR machine, and hence whether ...
2 |
1 |
6k |
answers |
votes |
views |
Hello nmr wikier I want to run pulprog h2bcetgpl3 on bruker instrument using adiabiatic shape pulse crp60comp.4 I determ...
2 |
1 |
16368 |
answers |
votes |
views |
On our Avance III 500 we use Topshim quite successfully for any probe with a gradient coil. The only time we have a pro...
3 |
0 |
5k |
answers |
votes |
views |
Dear friends,
I am now trying to record the NOESY spectrum of my 30 amino acids peptide on DRX600 with a TXI cryo probe...
1 |
1 |
6k |
answers |
votes |
views |
Hi NMRwikiers, for measuring scalar couplings we use some HSQC pulse sequences modified for obtaining the coupling in F1...
1 |
1 |
6k |
answers |
votes |
views |
Was trying to lift sample in BMSB control suite... but the machine detected sample within and an error 113 popped out. A...
2 |
1 |
4k |
answers |
votes |
views |
hi, though this question seems to be easy for you but i am new for this software and to this field. Recently, i took sil...
Updated:
Ganesh
21
Apr 24 '11 at 23:28
0 |
1 |
4k |
answers |
votes |
views |
Hi, I was asked to study polyethylene degradated by gamma and Xrays. I planed to measure relaxations rates, but which on...
1 |
0 |
6k |
answers |
votes |
views |
I'm a little bit confused about setting o1, in the case of a solid sample
First o1 is the offset of the transmitter fre...
6 |
1 |
19997 |
answers |
votes |
views |
To experienced Bruker users:
I often get the following message in ICON-NMR while running HSQC/HMQC:
"zg: DRU warning: n ...
0 |
1 |
3k |
answers |
votes |
views |
Hello,
I am a novie to the field. I am trying to record the change in settings post shimming using Bruker ParaVision. I...
6 |
1 |
9k |
answers |
votes |
views |
Hello people,
For my internship I am attempting to fully automate monomer composition analysis on Bruker TOPSPIN 2.0 us...