Tagged questions

can I have Topspin/XWIN-NMR run a paralell cmd on every `zg`?

0 0 23334
answers votes views
Hi, I wanna Brukers TopSpin/XWIN-NMR to log the start and end times of every experiment. With this information I can ...
Posted: oxy 31 Aug 28 '19 at 01:42

Bruker pulse program for PENDANT experiment

0 0 5k
answers votes views
Hi there, I am looking for the pulse program for the PENDANT experiment, for a Bruker Avance III spectrometer, has anyon...
Posted: AnneBaudouin 1 Aug 13 '18 at 07:05

Tune and decoupling problems Bruker Avance 300

0 0 11486
answers votes views
Hello everyone, I had to change a BVT3300 module in a Bruker Avance 300 console today. Everytihing went fine and the mo...
Updated: gael58 1 Feb 22 '18 at 07:45

Why SR(F1) in hcchtocsy and h(cc)(co)nh?

0 0 8k
answers votes views
Hi,All, I wonder if somebody can tell me why in these two experiments( also hbha(co)nh,I think) in Bruker(not sure if yo...
Updated: blue 1 Feb 28 '17 at 08:37

Difference between H 50 W and X 100 W Amplifiers

2 0 3k
answers votes views
We have been trying to get a 2D H-F experiment to work using the X 100 W amplifier on our Bruker NMR, but can't get it t...
Posted: ysuh 1 / Updated: Kirk Marat 711 Jun 14 '16 at 11:55

Amplitude problems when comparing 'popt' experiments in Bruker (Topspin)

0 0 9k
answers votes views
Hi all, My question is about the Multiple Display (.md) function on TopSpin (Bruker AVIII). I did some 'popt' ( paramete...
Posted: TiagoB1 1 Nov 11 '15 at 03:40

Partially Parallel Imaging

0 0 1k
answers votes views
I am running Paravision 4.0 from Topsin 1.5 with one receiver coil. I would like to increase the PPI acceleration factor...
Posted: adam 1 Jul 21 '15 at 05:18

Bruker AV500 TOPSHIM error

1 0 5k
answers votes views
Hi, I'm having a problem with topshim on Bruker AV 500 using topspin 2.1. it finishes with error (topshim: FieldMap - no...
Posted: jrlopez 1 / Updated: Jim Lin 1 Apr 14 '15 at 06:23

reading Bruker phase data

1 0 3k
answers votes views
Hi all, I'm having trouble reading the 2dseq file for a scan I ran. It should contain 2 slices of 66x50 voxels, repeate...
Updated: Nicholas E 11 Mar 13 '15 at 10:53

WaterLOGSY pulse program for bruker

1 0 6k
answers votes views
Hello, I was wondering if there was a waterLOGSY sequence among the bruker sequences. If not, could someone tell me whe...
Posted: gravatar 83 / Updated: Arkadiusz Leniak 238 Mar 17 '15 at 08:09

Topshim error

2 0 9k
answers votes views
HELLO all nmr wikier,I am facing problem in runing topshim on bruker 500Mhz using topspin 2.1 it finishes with error (fi...
Posted: feroon 21 / Updated: Jim Lin 1 Mar 31 '15 at 06:19

Any decent nmr processing software for free?

5 0 7k
answers votes views
Hello people, Does anyone know of any free NMR software (no trials, I can't stand it anymore) that is robust enough to ...
Posted: gravatar 83 / Updated: Craig 41 Mar 05 '15 at 01:45

Parameters for zgesfpgp 1d experiment (flipback watergate) on Bruker

1 0 3k
answers votes views
Hi , Does any one know how to set up the zgesfpgp 1d experiment (flipback water gate) on Bruker. I am looking for p29 du...
Posted: sri 71 / Updated: Clemens Anklin 416 Mar 03 '15 at 20:41

Can anyone point me towards a waterlogsy tutorial for bruker?

0 0 1k
answers votes views
Hello people, It's all in the title. ...
Posted: gravatar 83 Feb 02 '15 at 08:15

Predicting aquisition time needed depending on sample concentration

2 0 7k
answers votes views
Hi , is there a way of predicting aquisition time needed depending on sample concentration in order to get a decent spe...
Posted: gravatar 83 / Updated: clemistry 1 May 19 '15 at 14:36

Running a wet sequence

2 0 6k
answers votes views
Hi, I am trying to run a wet sequence but I'm having trouble getting good results on a sample with 90:10 water:methanol...
Posted: gravatar 83 / Updated: Pete Gierth 401 Dec 05 '14 at 10:35

What is the actual point of dummy scans?

3 0 13812
answers votes views
Hi, I was wondering why so many pulse programs use dummy scans. Correct me if I'm wrong but I think dummy scans are supp...
Posted: gravatar 83 / Updated: Pete Gierth 401 Dec 05 '14 at 10:44

au for 1H and 31P with iexpno and ssleep for kinetics

1 0 3k
answers votes views
hi there. I want to establish an au with the following content: I want to measure 1H and 31P make ssleep (userdefined)...
Posted: charlez miller 1 / Updated: Ulrich Haunz 210 Sep 22 '14 at 06:25

Which Bruker HSQC program do you use?

5 0 9k
answers votes views
Hello, could you tell me which HSQC and E-HSQC program are recommendable ? These are Bruker HSQC pulse programs: hsqcp...
Posted: lithiumamide 1 / Updated: RuudA 11 Sep 10 '14 at 11:46

Tool for Subsampling Uniformly-Acquired Data to Mimic NUS Spectra

1 0 8k
answers votes views
Hello all, I have several 2D and 3D data sets acquired using Bruker spectrometers in the standard uniform sampling fash...
Updated: ChemMJW 99 Aug 23 '14 at 20:43

15N 90 degree hard pulse calibration

4 0 25398
answers votes views
Greetings, I want to ask for some advice in matter of 15N hard pulse calibration on Bruker machines. I'm working on Avan...
Updated: Arkadiusz Leniak 238 Aug 25 '14 at 04:18

Topspin 2.1 error message with Windows 7 OS

3 0 7k
answers votes views
Hi all, I have been running TopSpin 2.1 on my Windows 7 32-bit OS for the last few years and now am getting this annoyin...
Posted: Olivia 1 / Updated: Ulrich Haunz 210 Nov 14 '14 at 03:16

Topspin3.2 deconvolution, border peaks are cutted off

1 0 5k
answers votes views
Greetings, I've some annoying issue with Topspin and deconvolution. No matter what I'm trying to do, border peaks are a...
Posted: Arkadiusz Leniak 238 / Updated: Ulrich Haunz 210 Jun 16 '14 at 07:48

19F full range homodecoupling

3 0 7k
answers votes views
Greetings, this is my first question in this wiki :) I wonder if there's possibility to obtain full homo decoupled spe...
Updated: Arkadiusz Leniak 238 Jun 16 '14 at 00:14

bruker s1 sortier

0 0 4k
answers votes views
Hello, I can't get results, as unknown error occures data/results.csv I'd restarted spectrometr several time, but the s...
Posted: Konservator 1 / Updated: Jerry Hirschinger 199 May 06 '14 at 07:37

How to performing acquisition during all time multi pulse sequence - Bruker ?

1 0 71861
answers votes views
Hi all, I have a small question on how to aquired a complete signal in BRUKER AVIII. I want to create a multi pulse sequ...
Posted: TiagoB 5 / Updated: Pascal Fricke 236 Oct 11 '13 at 06:59

Reset F1 axis (Bruker)

1 0 3k
answers votes views
Hi all, I have a 2D Bruker dataset that took a while to acquire, so I'd rather not simply repeat it. However, it seems...
Updated: wilsonmv 1 Aug 11 '13 at 22:12

How to start experiment at particular row

1 0 3k
answers votes views
I was running a 3D 15N edit NOESY (on a Bruker 600) and it was inadvertently stopped. I would like to restart the experi...
Posted: Lola Brown 1 / Updated: Pete Gierth 401 Jun 13 '13 at 11:05

Avance III 400 NMR lift unresponsive... emergency air lift activiated

1 0 8k
answers votes views
Hi, I am unable to activate our lift on our avance III 400 NMR from BruKer The message is emergency air lift activated....
Posted: Tamara 1 / Updated: wilsonmv 1 May 27 '13 at 18:53

Bruker Minispec mq40. What is the daily check sample?

1 0 4k
answers votes views
Hello all, Our daily check sample for the Minispec mq40 has been decreased in volume due to probably evaporation!! An...
Posted: Amin os 43 / Updated: Xenia Tombokan 1 Apr 11 '13 at 08:43
75

questions tagged

bruker

Newest questions are shown first.

Tags

× 75
× 34
× 33
× 26
× 26
× 25
× 24
× 15
× 11
× 10
× 10
× 9
× 9
× 8
× 8
× 7
× 7
× 7
× 6
× 6
× 5
× 5
× 5
× 4
× 3
× 3
× 3
× 2
× 2
× 2
× 2
× 2
× 2
× 2
× 2
× 2
× 2
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1
posts per page103050

powered by CNPROG