7 |
2 |
11209 |
answers |
votes |
views |
Hello,
Here are Bruker hmbc pulse programs (produced by ls *hmbc*):
hmbcacbigpl2ndqf hmbcacgplpqf hmbcetgpl2nd hm...
6 |
1 |
9k |
answers |
votes |
views |
Hello people,
For my internship I am attempting to fully automate monomer composition analysis on Bruker TOPSPIN 2.0 us...
6 |
1 |
21907 |
answers |
votes |
views |
To experienced Bruker users:
I often get the following message in ICON-NMR while running HSQC/HMQC:
"zg: DRU warning: n ...
5 |
0 |
17447 |
answers |
votes |
views |
Hello, I would like to find detailed technical info on the binary data storage formats for Varian and Bruker. Could anyo...
5 |
0 |
8k |
answers |
votes |
views |
Hello people,
Does anyone know of any free NMR software (no trials, I can't stand it anymore) that is robust enough to ...
5 |
0 |
10524 |
answers |
votes |
views |
Hello, could you tell me which HSQC and E-HSQC program are recommendable ?
These are Bruker HSQC pulse programs:
hsqcp...
4 |
1 |
26507 |
answers |
votes |
views |
Hi and thanks for answering my prev. questions! Decided to ask this one:
How can I convert fid data (ser file) to plain...
4 |
0 |
25692 |
answers |
votes |
views |
Greetings,
I want to ask for some advice in matter of 15N hard pulse calibration on Bruker machines.
I'm working on Avan...
3 |
1 |
9k |
answers |
votes |
views |
Hello, may I ask this - NMR experiments/pulse sequences are available to assign aromatic sidechains - Phe, Tyr, Trp? We'...
Posted:
anita
31
/ Updated:
roseyp
46
Feb 22 '11 at 09:38
3 |
1 |
6k |
answers |
votes |
views |
Found a following statement in the pulse program called selnogp
p12:sp2:f1 ph2:r
What does this do - specifically las...
3 |
1 |
10393 |
answers |
votes |
views |
Hi all,
I am very new to nmrPipe. I want to achieve the following steps. It would be very kind if somebody helps.
I hav...
3 |
0 |
5k |
answers |
votes |
views |
Dear friends,
I am now trying to record the NOESY spectrum of my 30 amino acids peptide on DRX600 with a TXI cryo probe...
3 |
0 |
11144 |
answers |
votes |
views |
I am working on a MAS solid-state NMR Bruker spectrometer using Topspin. Is anyone familiar with a macro for running sev...
3 |
1 |
7k |
answers |
votes |
views |
I've received a loaner probe from Bruker while ours is being repaired but I'm not getting any timely response on instruc...
3 |
0 |
7k |
answers |
votes |
views |
Greetings,
this is my first question in this wiki :)
I wonder if there's possibility to obtain full homo decoupled spe...
3 |
0 |
7k |
answers |
votes |
views |
Hi all, I have been running TopSpin 2.1 on my Windows 7 32-bit OS for the last few years and now am getting this annoyin...
3 |
0 |
17114 |
answers |
votes |
views |
Hi,
I was wondering why so many pulse programs use dummy scans. Correct me if I'm wrong but I think dummy scans are supp...
2 |
2 |
9k |
answers |
votes |
views |
For some reason the shape tool has some sort of glitch that I can't calculate a power level for a wurst 10 ms pulse 180 ...
Posted:
roseyp
46
/ Updated:
djh
1
Aug 11 '11 at 04:14
2 |
2 |
16785 |
answers |
votes |
views |
Hi guys :
This post is related to : qa.nmrwiki.org/question/83/where-to-find-technical-information-on-varian-and-bruke...
Updated:
j
131
May 25 '10 at 11:45
2 |
1 |
5k |
answers |
votes |
views |
Hi guys :
Is there a public database of sample Bruker/Varian NMR spectra ? I want to look at a sample 4D SER file ......
2 |
2 |
40344 |
answers |
votes |
views |
I used to use Varian Inova systems with BioPack all the time, and now I'm using a Bruker Avance-III system geared for Ch...
2 |
0 |
5k |
answers |
votes |
views |
hi,i want to run NOESYPHPR with increment time as zero (d0=0).If possible, which software is easy to stack plot(in 1D-fo...
2 |
1 |
11596 |
answers |
votes |
views |
I am new to working with Bruker-style NMR data and am experiencing confusion with regard to Bruker's digital filtering. ...
2 |
1 |
6k |
answers |
votes |
views |
We try to setup a used Bruker Avance 200 system. After frequency search we started to setup lock and shim file. Using D2...
2 |
1 |
4k |
answers |
votes |
views |
hi, though this question seems to be easy for you but i am new for this software and to this field. Recently, i took sil...
Updated:
Ganesh
21
Apr 24 '11 at 23:28
2 |
1 |
17728 |
answers |
votes |
views |
On our Avance III 500 we use Topshim quite successfully for any probe with a gradient coil. The only time we have a pro...
2 |
1 |
15804 |
answers |
votes |
views |
Hi All,
This may be a daft question, but how do I go about identifying the probe in our NMR machine, and hence whether ...
2 |
1 |
6k |
answers |
votes |
views |
Hello nmr wikier I want to run pulprog h2bcetgpl3 on bruker instrument using adiabiatic shape pulse crp60comp.4 I determ...
2 |
0 |
12448 |
answers |
votes |
views |
I need to set up 2H NMR on a Bruker 600 MHz BBO probe for the first time. Can anyone give me a set of instructions?
Do ...
2 |
1 |
5k |
answers |
votes |
views |
Hi everyone
I would like to write some code to read in spectra that were processed using TopSpin (Bruker), but so far I...