0 |
0 |
3k |
answers |
votes |
views |
Does anyone notice that the Future actions (wbs,wnt,et al) won't work in VnmrJ 3.2?
In previous version VnmrJ, the wbs/w...
Posted:
Zhang
1
Jun 27 '18 at 03:30
0 |
0 |
9k |
answers |
votes |
views |
Dear all,
I want to write a macro that run lock, gradient shimming and acquisition in VnmrJ. I tried two ways, but fail...
Updated:
Zhang
1
Sep 24 '17 at 18:43
3 |
0 |
11716 |
answers |
votes |
views |
I have been trying to open varian vnmrj spectra in mnova software to workup the spectra, but I keep getting error messag...
3 |
1 |
6k |
answers |
votes |
views |
Hey folks, I was wondering if anyone else has had any issues with the experiments/pulse sequences that came standard in ...
1 |
0 |
4k |
answers |
votes |
views |
The default parameter setting for Acetic Acid seems to be setting the Lock Power to two. This is a problem when running...
0 |
0 |
3k |
answers |
votes |
views |
I am hoping to get some help for setting up a macro to get the NMR to find z0 and auto-shim onto a standard sample after...
1 |
1 |
3k |
answers |
votes |
views |
When I try to launch the spincad utility in the command line of VNMRJ v. 2.2c I get the following error:
Error in start...
Updated:
dkubicki
11
Nov 01 '11 at 11:26
4 |
0 |
8k |
answers |
votes |
views |
Dear Friends,
I've recently encountered a problem with gradient shimming that has never happened to me before. I can't ...
2 |
1 |
5k |
answers |
votes |
views |
Hi I am working on a Varian 500MHz NMR. I am attempting to use the pulse sequence satxfer1D to measure the rate constant...
1 |
1 |
4k |
answers |
votes |
views |
Hi, dear all,
I try to use garp1 sequence for decoupling with the statement " obsprgon("garp1", pw, angle, 0) ".
If an...
Updated:
Frey
61
Jun 30 '11 at 06:14
5 |
1 |
8k |
answers |
votes |
views |
Dear NMR wiki ers
Iam working on protein family which can form dimers (total 20kd size )
using 25mM TRIS , 100 mM KCL...
Updated:
sri
71
Aug 25 '11 at 00:09
0 |
1 |
2k |
answers |
votes |
views |
I have been trying to use the command 'proj' (in vnmrj 2.1) with a given frequencey and frequency range to do a sumn pro...
1 |
1 |
8k |
answers |
votes |
views |
Hello,
I was using VnmrJ to collect an array of 6 NMR spectra. I used VnmrJ to save all 6 spectra in 1 fid file by usin...
0 |
0 |
2k |
answers |
votes |
views |
when shimming with shimDriver, there may be an error message as 'usage - dfid or dfid#' and then the autoshim procedure ...
Posted:
Frey
61
Feb 26 '11 at 22:23
0 |
1 |
3k |
answers |
votes |
views |
when shimming with Fid scan, the fid/spectrum can't be displayed in real time.
...
Posted:
Frey
61
Feb 26 '11 at 22:22
0 |
0 |
3k |
answers |
votes |
views |
How can I change the line style of the spectrum or fid in viewports? The line of spectrum seems too narrow.
...
Updated:
Frey
61
Feb 26 '11 at 22:24
1 |
1 |
6k |
answers |
votes |
views |
I'm trying to display a 3D Varian file in VNMRJ. I can see values in the fid file (using the "od" utility) and convert t...
4 |
3 |
8k |
answers |
votes |
views |
Dear all,
I was wondering whether someone managed to install the VnmrJ software of Varian (2.2 D) on a Ubuntu based sys...
2 |
2 |
7k |
answers |
votes |
views |
Hi guys : Im trying to make a procpar for an FID, I know most of the parameters of importance, and have the schema of th...