Tagged questions

Macro for variable temperature experiments on Topspin (Bruker)

3 0 10748
answers votes views
I am working on a MAS solid-state NMR Bruker spectrometer using Topspin. Is anyone familiar with a macro for running sev...
Posted: Gili Abr 1 / Updated: David O'Brien 1 Apr 25 '12 at 08:32

Bruker Avance pulse sequences - where to find if not in TopSpin?

2 2 40023
answers votes views
I used to use Varian Inova systems with BioPack all the time, and now I'm using a Bruker Avance-III system geared for Ch...
Posted: jkurutz 131 / Updated: Charlie Fry 91 Aug 08 '10 at 09:34

Different proton Carrier frequencies

2 1 6k
answers votes views
Hi, I am a new member to this community. I would like to set up an experiment, in which I have to set up proton carrier ...
Posted: kmd 11 / Updated: Evgeny Fadeev 5771 Aug 19 '10 at 10:27

Is it possible to keep increment time as zero in 2D?

2 0 5k
answers votes views
hi,i want to run NOESYPHPR with increment time as zero (d0=0).If possible, which software is easy to stack plot(in 1D-fo...
Posted: saship21 21 / Updated: Evgeny Fadeev 5771 Nov 11 '10 at 20:35

help on creating a program similar to multizg?

2 1 6k
answers votes views
I am currently trying to write a program that is a lot like the multizg program in the Bruker software, Topspin but with...
Posted: Artjom Nepryahin 11 / Updated: John Hollerton 96 Dec 10 '12 at 10:05

Are hardcoded values in bruker pulse sequences overridable?

1 0 4k
answers votes views
For example when there is a statement like this in the pulse program file "d12=20u" can I change value of d12 from th...
Posted: Evgeny Fadeev 5771 / Updated: Clemens Anklin 416 Jul 28 '10 at 02:07

Problem with both dispersed and absorbed peaks

1 1 5k
answers votes views
hi when i run homonuclear NOESY experiments in bruker 500MHz spectometer with d8 150ms(mw is 300).Though i am followi...
Updated: Ganesh 21 Apr 24 '11 at 23:21

CT COSY pulse sequence programming

1 1 5k
answers votes views
Hi, I want to make a CT-COSY pulse sequence on a Brucker AVANCE II spectrometer. But I'm bother by incremented delay. W...
Posted: dimichu 11 / Updated: Clemens Anklin 416 May 07 '11 at 03:38

modulo or integer division in topspin

1 0 4k
answers votes views
Hi! is there a possibility to perform an integer division or a modulo calculation in topspin 2.1? Thank you! ...
Posted: guma 1 / Updated: Clemens Anklin 416 Sep 06 '11 at 11:47

Amplifier Error

1 0 3k
answers votes views
Hi All, I am worikng with 500Mhz Bruker. Recently 3rd channel is installed in my institute when i run 3D HNCA experime...
Posted: saship21 21 / Updated: sekhar Talluri 621 Oct 21 '12 at 07:05

How to implement receiver phase toggle in XWINNMR?

1 0 4k
answers votes views
How does one change the receiver phase DURING stroboscopic acquisition in XWINNMR? The "ipp" commands do not seem to wor...
Updated: forza 1 Nov 10 '16 at 10:22

Switiching off the receiver during acquisition

0 0 2k
answers votes views
Hello nmr wikier. I use Bruker Avance I AQS 400. TopSpin Version 1.3 For a test I want to switch off the receiver durin...
Posted: Mario 1 Sep 13 '11 at 05:27

Pulse sequence for homonuclear correlation with SPC5 mixing period

0 0 7k
answers votes views
Hi, I'm looking for a pulse program suitable for Bruker Avance llI (topspin 2.1) which is 2D homonuclear correlation wit...
Posted: Gili Abr 1 Sep 27 '12 at 02:09
13

questions tagged

pulse-programming

Questions sorted by the number of answers.

Tags

posts per page103050