Tagged questions

Partially Parallel Imaging

0 0 1k
answers votes views
I am running Paravision 4.0 from Topsin 1.5 with one receiver coil. I would like to increase the PPI acceleration factor...
Posted: adam 1 Jul 21 '15 at 05:18

Bruker AV500 TOPSHIM error

1 0 4k
answers votes views
Hi, I'm having a problem with topshim on Bruker AV 500 using topspin 2.1. it finishes with error (topshim: FieldMap - no...
Posted: jrlopez 1 / Updated: Jim Lin 1 Apr 14 '15 at 06:23

reading Bruker phase data

1 0 3k
answers votes views
Hi all, I'm having trouble reading the 2dseq file for a scan I ran. It should contain 2 slices of 66x50 voxels, repeate...
Updated: Nicholas E 11 Mar 13 '15 at 10:53

WaterLOGSY pulse program for bruker

1 0 5k
answers votes views
Hello, I was wondering if there was a waterLOGSY sequence among the bruker sequences. If not, could someone tell me whe...
Posted: gravatar 83 / Updated: Arkadiusz Leniak 238 Mar 17 '15 at 08:09

Topshim error

2 0 8k
answers votes views
HELLO all nmr wikier,I am facing problem in runing topshim on bruker 500Mhz using topspin 2.1 it finishes with error (fi...
Posted: feroon 21 / Updated: Jim Lin 1 Mar 31 '15 at 06:19

What is the actual point of dummy scans?

3 0 12842
answers votes views
Hi, I was wondering why so many pulse programs use dummy scans. Correct me if I'm wrong but I think dummy scans are supp...
Posted: gravatar 83 / Updated: Pete Gierth 401 Dec 05 '14 at 10:44

Can anyone point me towards a waterlogsy tutorial for bruker?

0 0 1k
answers votes views
Hello people, It's all in the title. ...
Posted: gravatar 83 Feb 02 '15 at 08:15

Running a wet sequence

2 0 5k
answers votes views
Hi, I am trying to run a wet sequence but I'm having trouble getting good results on a sample with 90:10 water:methanol...
Posted: gravatar 83 / Updated: Pete Gierth 401 Dec 05 '14 at 10:35

Tool for Subsampling Uniformly-Acquired Data to Mimic NUS Spectra

1 0 7k
answers votes views
Hello all, I have several 2D and 3D data sets acquired using Bruker spectrometers in the standard uniform sampling fash...
Updated: ChemMJW 99 Aug 23 '14 at 20:43

Difference between H 50 W and X 100 W Amplifiers

2 0 3k
answers votes views
We have been trying to get a 2D H-F experiment to work using the X 100 W amplifier on our Bruker NMR, but can't get it t...
Posted: ysuh 1 / Updated: Kirk Marat 711 Jun 14 '16 at 11:55