Tagged questions

Topshim error

2 0 9k
answers votes views
HELLO all nmr wikier,I am facing problem in runing topshim on bruker 500Mhz using topspin 2.1 it finishes with error (fi...
Posted: feroon 21 / Updated: Jim Lin 1 Mar 31 '15 at 06:19

Any decent nmr processing software for free?

5 0 7k
answers votes views
Hello people, Does anyone know of any free NMR software (no trials, I can't stand it anymore) that is robust enough to ...
Posted: gravatar 83 / Updated: Craig 41 Mar 05 '15 at 01:45

Parameters for zgesfpgp 1d experiment (flipback watergate) on Bruker

1 0 3k
answers votes views
Hi , Does any one know how to set up the zgesfpgp 1d experiment (flipback water gate) on Bruker. I am looking for p29 du...
Posted: sri 71 / Updated: Clemens Anklin 416 Mar 03 '15 at 20:41

Can anyone point me towards a waterlogsy tutorial for bruker?

0 0 1k
answers votes views
Hello people, It's all in the title. ...
Posted: gravatar 83 Feb 02 '15 at 08:15

Predicting aquisition time needed depending on sample concentration

2 0 7k
answers votes views
Hi , is there a way of predicting aquisition time needed depending on sample concentration in order to get a decent spe...
Posted: gravatar 83 / Updated: clemistry 1 May 19 '15 at 14:36

Running a wet sequence

2 0 6k
answers votes views
Hi, I am trying to run a wet sequence but I'm having trouble getting good results on a sample with 90:10 water:methanol...
Posted: gravatar 83 / Updated: Pete Gierth 401 Dec 05 '14 at 10:35

What is the actual point of dummy scans?

3 0 14449
answers votes views
Hi, I was wondering why so many pulse programs use dummy scans. Correct me if I'm wrong but I think dummy scans are supp...
Posted: gravatar 83 / Updated: Pete Gierth 401 Dec 05 '14 at 10:44

au for 1H and 31P with iexpno and ssleep for kinetics

1 0 3k
answers votes views
hi there. I want to establish an au with the following content: I want to measure 1H and 31P make ssleep (userdefined)...
Posted: charlez miller 1 / Updated: Ulrich Haunz 210 Sep 22 '14 at 06:25

Which Bruker HSQC program do you use?

5 0 10181
answers votes views
Hello, could you tell me which HSQC and E-HSQC program are recommendable ? These are Bruker HSQC pulse programs: hsqcp...
Posted: lithiumamide 1 / Updated: RuudA 11 Sep 10 '14 at 11:46

Tool for Subsampling Uniformly-Acquired Data to Mimic NUS Spectra

1 0 8k
answers votes views
Hello all, I have several 2D and 3D data sets acquired using Bruker spectrometers in the standard uniform sampling fash...
Updated: ChemMJW 99 Aug 23 '14 at 20:43