what is importance of PH mode in topspin2.1

1 1 7k
answers votes views
hi,when i am processing nmr data in topspin 2.1,by default we are using pk mode in ph mode.there are other modes also su...
Posted: sashi 41 / Updated: Clemens Anklin 416 Jul 23 '10 at 21:21

What is the purpose of acqu and acqus files in Bruker setup?

1 1 32485
answers votes views
Hello, What is the significance of the "s" in the end of the parameter file name in the Bruker experiment directories?...
Posted: Evgeny Fadeev 5771 / Updated: Clemens Anklin 416 Jul 23 '10 at 21:16

T2 relaxation dispersion with Bruker's sequence

1 1 8k
answers votes views
Hi there, I've been trying to use bruker's pseudo-3D sequence for meassuring T2 relaxation dispersion and have a problem...
Posted: Luciano A 11 / Updated: Yoan Monneau 136 May 28 '11 at 03:56

COSY problem (cosydfesgpph pulse program)

1 1 4k
answers votes views
Hi, I am running COSY on a DNA:RNA hybrifd. However, I have got no cross-peaks at all even for CYT H5-H6? what do you ...
Posted: waleed 13 / Updated: Evgeny Fadeev 5771 Aug 31 '10 at 11:48

How to process and analyze serial 1D data nmrPipe?

3 1 9k
answers votes views
Hi all, I am very new to nmrPipe. I want to achieve the following steps. It would be very kind if somebody helps. I hav...
Posted: RSnmr 11 / Updated: Evgeny Fadeev 5771 Oct 28 '10 at 09:44

Bruker GRPDLY Parameter

2 1 10282
answers votes views
I am new to working with Bruker-style NMR data and am experiencing confusion with regard to Bruker's digital filtering. ...
Posted: ChemMJW 99 / Updated: Kirk Marat 711 Nov 15 '10 at 09:10

two lines in acetone-d6

2 1 5k
answers votes views
We try to setup a used Bruker Avance 200 system. After frequency search we started to setup lock and shim file. Using D2...
Posted: Thomas Tr 11 / Updated: Evgeny Fadeev 5771 Nov 19 '10 at 12:23

Exporting integral data for use in calculations

6 1 9k
answers votes views
Hello people, For my internship I am attempting to fully automate monomer composition analysis on Bruker TOPSPIN 2.0 us...
Posted: Nathanael91 23 / Updated: Clemens Anklin 416 Nov 30 '10 at 09:12

Where can I find current shim values in Bruker Paravision?

0 1 2k
answers votes views
Hello, I am a novie to the field. I am trying to record the change in settings post shimming using Bruker ParaVision. I...
Posted: cyclone 21 / Updated: Evgeny Fadeev 5771 Jan 04 '11 at 15:35

Bruker DRU ADC-overflow warning message in Topspin during HSQCEDETGP

6 1 18259
answers votes views
To experienced Bruker users: I often get the following message in ICON-NMR while running HSQC/HMQC: "zg: DRU warning: n ...
Posted: Sylvain Demanze 71 / Updated: djh 1 Aug 11 '11 at 02:49
75

questions tagged

bruker

Questions are sorted by the number of votes. Most voted questions are shown first.

Tags

× 75
× 33
× 24
× 15
× 10
× 8
× 8
× 7
× 6
× 5
× 4
× 4
× 3
× 3
× 3
× 2
× 2
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1
posts per page103050

powered by CNPROG