Tagged questions

Tool for Subsampling Uniformly-Acquired Data to Mimic NUS Spectra

1 0 224
answers votes views
Hello all, I have several 2D and 3D data sets acquired using Bruker spectrometers in the standard uniform sampling fash...
Updated: ChemMJW 99 Aug 23 at 20:43

15N 90 degree hard pulse calibration

4 0 105
answers votes views
Greetings, I want to ask for some advice in matter of 15N hard pulse calibration on Bruker machines. I'm working on Avan...
Updated: Arkadiusz Leniak 76 Aug 25 at 04:18

Topspin 2.1 error message with Windows 7 OS

1 0 286
answers votes views
Hi all, I have been running TopSpin 2.1 on my Windows 7 32-bit OS for the last few years and now am getting this annoyin...
Posted: Olivia 1 / Updated: w101bdk 7 Jul 30 at 10:38

Topspin3.2 deconvolution, border peaks are cutted off

1 0 211
answers votes views
Greetings, I've some annoying issue with Topspin and deconvolution. No matter what I'm trying to do, border peaks are a...
Posted: Arkadiusz Leniak 76 / Updated: Ulrich Haunz 164 Jun 16 at 07:48

19F full range homodecoupling

3 0 386
answers votes views
Greetings, this is my first question in this wiki :) I wonder if there's possibility to obtain full homo decoupled spe...
Updated: Arkadiusz Leniak 76 Jun 16 at 00:14

bruker s1 sortier

0 0 216
answers votes views
Hello, I can't get results, as unknown error occures data/results.csv I'd restarted spectrometr several time, but the s...
Posted: Konservator 1 / Updated: Jerry Hirschinger 189 May 06 at 07:37

How to performing acquisition during all time multi pulse sequence - Bruker ?

1 0 19785
answers votes views
Hi all, I have a small question on how to aquired a complete signal in BRUKER AVIII. I want to create a multi pulse sequ...
Posted: TiagoB 5 / Updated: Pascal Fricke 236 Oct 11 '13 at 06:59

Reset F1 axis (Bruker)

1 0 821
answers votes views
Hi all, I have a 2D Bruker dataset that took a while to acquire, so I'd rather not simply repeat it. However, it seems...
Updated: wilsonmv 1 Aug 11 '13 at 22:12

How to start experiment at particular row

1 0 759
answers votes views
I was running a 3D 15N edit NOESY (on a Bruker 600) and it was inadvertently stopped. I would like to restart the experi...
Posted: Lola Brown 1 / Updated: Pete Gierth 326 Jun 13 '13 at 11:05

Avance III 400 NMR lift unresponsive... emergency air lift activiated

1 0 1k
answers votes views
Hi, I am unable to activate our lift on our avance III 400 NMR from BruKer The message is emergency air lift activated....
Posted: Tamara 1 / Updated: wilsonmv 1 May 27 '13 at 18:53
56

questions tagged

bruker

Newest questions are shown first.

Tags

× 56
× 32
× 25
× 23
× 18
× 10
× 6
× 5
× 5
× 5
× 4
× 3
× 2
× 2
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1
posts per page103050

powered by CNPROG