Running a wet sequence

1 0 27
answers votes views
Hi, I am trying to run a wet sequence but I'm having trouble getting good results on a sample with 90:10 water:methanol...
Posted: gravatar 49 / Updated: Arkadiusz Leniak 152 Nov 21 at 01:46

What is the actual point of dummy scans?

3 0 92
answers votes views
Hi, I was wondering why so many pulse programs use dummy scans. Correct me if I'm wrong but I think dummy scans are supp...
Posted: gravatar 49 / Updated: Arkadiusz Leniak 152 Nov 18 at 00:03

au for 1H and 31P with iexpno and ssleep for kinetics

1 0 430
answers votes views
hi there. I want to establish an au with the following content: I want to measure 1H and 31P make ssleep (userdefined)...
Posted: charlez miller 1 / Updated: Ulrich Haunz 167 Sep 22 at 06:25

Which Bruker HSQC program do you use?

5 0 683
answers votes views
Hello, could you tell me which HSQC and E-HSQC program are recommendable ? These are Bruker HSQC pulse programs: hsqcp...
Posted: lithiumamide 1 / Updated: RuudA 11 Sep 10 at 11:46

Tool for Subsampling Uniformly-Acquired Data to Mimic NUS Spectra

1 0 4k
answers votes views
Hello all, I have several 2D and 3D data sets acquired using Bruker spectrometers in the standard uniform sampling fash...
Updated: ChemMJW 99 Aug 23 at 20:43

15N 90 degree hard pulse calibration

4 0 5k
answers votes views
Greetings, I want to ask for some advice in matter of 15N hard pulse calibration on Bruker machines. I'm working on Avan...
Updated: Arkadiusz Leniak 152 Aug 25 at 04:18

Topspin 2.1 error message with Windows 7 OS

3 0 757
answers votes views
Hi all, I have been running TopSpin 2.1 on my Windows 7 32-bit OS for the last few years and now am getting this annoyin...
Posted: Olivia 1 / Updated: Ulrich Haunz 167 Nov 14 at 03:16

Topspin3.2 deconvolution, border peaks are cutted off

1 0 773
answers votes views
Greetings, I've some annoying issue with Topspin and deconvolution. No matter what I'm trying to do, border peaks are a...
Posted: Arkadiusz Leniak 152 / Updated: Ulrich Haunz 167 Jun 16 at 07:48

19F full range homodecoupling

3 0 2k
answers votes views
Greetings, this is my first question in this wiki :) I wonder if there's possibility to obtain full homo decoupled spe...
Updated: Arkadiusz Leniak 152 Jun 16 at 00:14

bruker s1 sortier

0 0 1k
answers votes views
Hello, I can't get results, as unknown error occures data/results.csv I'd restarted spectrometr several time, but the s...
Posted: Konservator 1 / Updated: Jerry Hirschinger 189 May 06 at 07:37