two lines in acetone-d6

2 1 6k
answers votes views
We try to setup a used Bruker Avance 200 system. After frequency search we started to setup lock and shim file. Using D2...
Posted: Thomas Tr 11 / Updated: Evgeny Fadeev 5771 Nov 19 '10 at 12:23

Bruker GRPDLY Parameter

2 1 11171
answers votes views
I am new to working with Bruker-style NMR data and am experiencing confusion with regard to Bruker's digital filtering. ...
Posted: ChemMJW 99 / Updated: Kirk Marat 711 Nov 15 '10 at 09:10

Is it possible to keep increment time as zero in 2D?

2 0 5k
answers votes views
hi,i want to run NOESYPHPR with increment time as zero (d0=0).If possible, which software is easy to stack plot(in 1D-fo...
Posted: saship21 21 / Updated: Evgeny Fadeev 5771 Nov 11 '10 at 20:35

How to process and analyze serial 1D data nmrPipe?

3 1 10187
answers votes views
Hi all, I am very new to nmrPipe. I want to achieve the following steps. It would be very kind if somebody helps. I hav...
Posted: RSnmr 11 / Updated: Evgeny Fadeev 5771 Oct 28 '10 at 09:44

COSY problem (cosydfesgpph pulse program)

1 1 4k
answers votes views
Hi, I am running COSY on a DNA:RNA hybrifd. However, I have got no cross-peaks at all even for CYT H5-H6? what do you ...
Posted: waleed 13 / Updated: Evgeny Fadeev 5771 Aug 31 '10 at 11:48

T2 relaxation dispersion with Bruker's sequence

1 1 8k
answers votes views
Hi there, I've been trying to use bruker's pseudo-3D sequence for meassuring T2 relaxation dispersion and have a problem...
Posted: Luciano A 11 / Updated: Yoan Monneau 136 May 28 '11 at 03:56

vconv - cannot open menu with too many items

0 0 3k
answers votes views
Hi I was trying to open varian data on a bruker XWinNMR software - typed vconv command and there was an error that sound...
Posted: Evgeny Fadeev 5771 Aug 13 '10 at 13:33

Bruker Avance pulse sequences - where to find if not in TopSpin?

2 2 40049
answers votes views
I used to use Varian Inova systems with BioPack all the time, and now I'm using a Bruker Avance-III system geared for Ch...
Posted: jkurutz 131 / Updated: Charlie Fry 91 Aug 08 '10 at 09:34

Are hardcoded values in bruker pulse sequences overridable?

1 0 4k
answers votes views
For example when there is a statement like this in the pulse program file "d12=20u" can I change value of d12 from th...
Posted: Evgeny Fadeev 5771 / Updated: Clemens Anklin 416 Jul 28 '10 at 02:07

What is the purpose of acqu and acqus files in Bruker setup?

1 1 32870
answers votes views
Hello, What is the significance of the "s" in the end of the parameter file name in the Bruker experiment directories?...
Posted: Evgeny Fadeev 5771 / Updated: Clemens Anklin 416 Jul 23 '10 at 21:16