Tagged questions

Problem with both dispersed and absorbed peaks

1 1 850
answers votes views
hi when i run homonuclear NOESY experiments in bruker 500MHz spectometer with d8 150ms(mw is 300).Though i am followi...
Updated: Ganesh 21 Apr 24 '11 at 23:21

incorrect processing of 2D HSQC in NMRPipe - what is wrong?

3 1 887
answers votes views
i'm trying to process an HSQC by using standard scripts of NMRpipe, and get this: what is wrong in my processing? at...
Posted: nadia1230 11 / Updated: TJCarruthers 31 Apr 19 '11 at 16:10

Processing 1D FID of ethanol exported from spinworks

1 1 929
answers votes views
Hello, This is probably a basic question, alas it has caused considerable turmoil, so at the risk of embarrassing mysel...
Posted: jeffery 13 / Updated: Kirk Marat 523 Oct 12 '10 at 20:11

How to fix the broad antiphase artifact after SOL function in nmrPipe?

2 0 1k
answers votes views
Hi, we've tried to apply SOL function of nmrPipe to process a 3D 13C edited NOESY. and the result is a wide antiphase-lo...
Posted: Evgeny Fadeev 5081 / Updated: sekhar Talluri 526 Apr 26 '11 at 11:04

What is the meaning of "no dba open" message in felix?

1 1 804
answers votes views
hi, while i processing data(1-D r 2-D)in felix software,i frequently encountered by "no dba open"this problem, what d...
Posted: saship21 21 / Updated: Steve 41 Aug 07 '10 at 20:18

How to create synthetic FID data in either Bruker, Varian or JEOL?

3 0 1k
answers votes views
Are there tools that allow to create raw data files in vendor format that contain desired data? For example for the tes...
Posted: Evgeny Fadeev 5081 / Updated: John Hollerton 86 Aug 24 '10 at 06:55

Problem reading and transforming vendor data using C++/Qt

3 2 1k
answers votes views
Hi, I am a German chemistry Bachelor student (beginning my Master studies in October) and as a spare-time hobby I would...
Updated: Pascal Fricke 51 Aug 04 '10 at 00:16

what is standard procedure for importing data to topspin2.1

1 1 680
answers votes views
hi,i am unable to import some nmr file which are stored in D or some other drives.. can anybody help me please thankyou ...
Posted: sashi 41 / Updated: Evgeny Fadeev 5081 Jul 19 '10 at 13:25

how to import bruker data to felix

1 1 972
answers votes views
hi,we have bruker(avance)-500Mhz nmr spectrometer ,topspin 2.0 is inbuilt software for this ,when i trasfer this data to...
Posted: sashi 41 / Updated: Evgeny Fadeev 5081 Jul 18 '10 at 23:01

NMRPipe: Why Varian States-TPPI NMR data is to be processed with -yMode Complex?

1 0 1k
answers votes views
Hello, I've started using Varian instrument at UCI two years ago and I use nmrPipe to process the data. This one thing ...
Posted: Evgeny Fadeev 5081 / Updated: Clemens Anklin 276 Jun 06 '10 at 15:14