Tagged questions

Predicting aquisition time needed depending on sample concentration

2 0 6k
answers votes views
Hi , is there a way of predicting aquisition time needed depending on sample concentration in order to get a decent spe...
Posted: gravatar 83 / Updated: clemistry 1 May 19 '15 at 14:36

Topshim error

2 0 8k
answers votes views
HELLO all nmr wikier,I am facing problem in runing topshim on bruker 500Mhz using topspin 2.1 it finishes with error (fi...
Posted: feroon 21 / Updated: Jim Lin 1 Mar 31 '15 at 06:19

Running a wet sequence

2 0 5k
answers votes views
Hi, I am trying to run a wet sequence but I'm having trouble getting good results on a sample with 90:10 water:methanol...
Posted: gravatar 83 / Updated: Pete Gierth 401 Dec 05 '14 at 10:35

Difference between H 50 W and X 100 W Amplifiers

2 0 3k
answers votes views
We have been trying to get a 2D H-F experiment to work using the X 100 W amplifier on our Bruker NMR, but can't get it t...
Posted: ysuh 1 / Updated: Kirk Marat 711 Jun 14 '16 at 11:55

Saturation transfer difference TROSY

1 1 10490
answers votes views
Has anyone added a pulse scheme for cross saturation to their TROSY for Bruker platform? Could you share a pulse sequen...
Posted: roseyp 46 / Updated: Jana 31 May 17 '13 at 22:46

Is value of default channel power ignored in Bruker systems for the shaped pulses?

1 0 32583
answers votes views
Hello, been editing a wiki page on the subject and this question occurred: For a Bruker pulse sequence in the following...
Posted: Evgeny Fadeev 5771 / Updated: Tony Bielecki 131 Mar 30 '10 at 19:11

What does tcu error in bruker mean: ignored AQNEXT, busy FIFO is stopped?

1 0 9k
answers votes views
Has any one seen this type of error before? tcu error: Error in 'hsqcrexetf3gpsi3d.t22.d': line 92 (pc=50, ld=2300): - ...
Posted: Jeetender Chugh 31 / Updated: Ilango 171 Jul 09 '10 at 11:45

What does prosol relations statement do in Bruker pulse program code?

1 0 12834
answers votes views
Hello, I found this in a pulse program called wet: prosol relations=<lcnmr> How does it affect the workings of...
Posted: Evgeny Fadeev 5771 / Updated: Ilango 171 Jul 16 '10 at 11:18

what is importance of PH mode in topspin2.1

1 1 7k
answers votes views
hi,when i am processing nmr data in topspin 2.1,by default we are using pk mode in ph mode.there are other modes also su...
Posted: sashi 41 / Updated: Clemens Anklin 416 Jul 23 '10 at 21:21

What is the purpose of acqu and acqus files in Bruker setup?

1 1 32466
answers votes views
Hello, What is the significance of the "s" in the end of the parameter file name in the Bruker experiment directories?...
Posted: Evgeny Fadeev 5771 / Updated: Clemens Anklin 416 Jul 23 '10 at 21:16