Tagged questions

File with description of parameters

1 0 4k
answers votes views
Hi, comrades! We use the linux version of TopSpin 2.1 as a software for AVANCE II Bruker 400 MHz. As I found parameters ...
Updated: Alexander Abakumov 11 Nov 19 '12 at 09:16

Avance III 400 NMR lift unresponsive... emergency air lift activiated

1 0 7k
answers votes views
Hi, I am unable to activate our lift on our avance III 400 NMR from BruKer The message is emergency air lift activated....
Posted: Tamara 1 / Updated: wilsonmv 1 May 27 '13 at 18:53

Topspin3.2 deconvolution, border peaks are cutted off

1 0 5k
answers votes views
Greetings, I've some annoying issue with Topspin and deconvolution. No matter what I'm trying to do, border peaks are a...
Posted: Arkadiusz Leniak 238 / Updated: Ulrich Haunz 210 Jun 16 '14 at 07:48

Tool for Subsampling Uniformly-Acquired Data to Mimic NUS Spectra

1 0 7k
answers votes views
Hello all, I have several 2D and 3D data sets acquired using Bruker spectrometers in the standard uniform sampling fash...
Updated: ChemMJW 99 Aug 23 '14 at 20:43

what does autoshim in the topspin bsms do?

1 0 5k
answers votes views
Hi, in the bsms gui there's an autoshim button. What does this function do exactly? Is it similar to topshim or is it a...
Posted: gravatar 83 / Updated: Ulrich Haunz 210 Aug 20 '14 at 06:16

1H 1D NMR data Normalization in Topspin.

1 0 4k
answers votes views
I have performed a series of 1H 1D experiments with different concentration of peptide and accordingly different numbers...
Posted: RBT 1 / Updated: Pete Gierth 401 Nov 23 '15 at 11:14

How to reference indirect dimensions in Topspin?

0 1 5k
answers votes views
Hello, When I process 3d data on topspin with the ft3d command, I get the three-dimensional spectra, but the chemical sh...
Posted: Gili 11 / Updated: Evgeny Fadeev 5771 Jul 26 '10 at 09:24

Pulse sequence for homonuclear correlation with SPC5 mixing period

0 0 6k
answers votes views
Hi, I'm looking for a pulse program suitable for Bruker Avance llI (topspin 2.1) which is 2D homonuclear correlation wit...
Posted: Gili Abr 1 Sep 27 '12 at 02:09

How to convert inversion recovery data acquired using Spinsight

0 0 3k
answers votes views
Hi, I do not know how to convert a data set acquired using Spinsight into a format that can be read by Topspin. The d...
Posted: mike 1 Nov 14 '13 at 14:00

Processing of spectra in Bruker Topspin

0 0 3k
answers votes views
Can anyone suggest important parameters need to be optimized for 3DNMR data processing and correct phasing of cross pea...
Updated: Arun Gupta 11 Jun 08 '14 at 03:04
33

questions tagged

topspin

Questions sorted by the number of answers.

Tags

× 75
× 34
× 33
× 26
× 25
× 24
× 13
× 11
× 8
× 8
× 4
× 3
× 2
× 2
× 1
× 1
× 1
× 1
× 1
× 1
× 1
× 1

powered by CNPROG