Is it possible to record EPR in THF (tetrahydrofuran) at -78C ?

0 0 6k
answers votes views
We've tried to measure an EPR spectrum of something in THF at -78C and could not tune the cavity on our Bruker EMX500 sp...
Updated: Evgeny Fadeev 5771 Feb 12 '10 at 15:52

Where to find technical information on Varian and Bruker data storage formats?

5 0 16663
answers votes views
Hello, I would like to find detailed technical info on the binary data storage formats for Varian and Bruker. Could anyo...
Posted: Evgeny Fadeev 5771 / Updated: arronlee 1 Jul 25 '14 at 00:00

Is value of default channel power ignored in Bruker systems for the shaped pulses?

1 0 32006
answers votes views
Hello, been editing a wiki page on the subject and this question occurred: For a Bruker pulse sequence in the following...
Posted: Evgeny Fadeev 5771 / Updated: Tony Bielecki 131 Mar 30 '10 at 19:11

What does tcu error in bruker mean: ignored AQNEXT, busy FIFO is stopped?

1 0 9k
answers votes views
Has any one seen this type of error before? tcu error: Error in 'hsqcrexetf3gpsi3d.t22.d': line 92 (pc=50, ld=2300): - ...
Posted: Jeetender Chugh 31 / Updated: Ilango 171 Jul 09 '10 at 11:45

What does prosol relations statement do in Bruker pulse program code?

1 0 12813
answers votes views
Hello, I found this in a pulse program called wet: prosol relations=<lcnmr> How does it affect the workings of...
Posted: Evgeny Fadeev 5771 / Updated: Ilango 171 Jul 16 '10 at 11:18

Are hardcoded values in bruker pulse sequences overridable?

1 0 4k
answers votes views
For example when there is a statement like this in the pulse program file "d12=20u" can I change value of d12 from th...
Posted: Evgeny Fadeev 5771 / Updated: Clemens Anklin 416 Jul 28 '10 at 02:07

vconv - cannot open menu with too many items

0 0 3k
answers votes views
Hi I was trying to open varian data on a bruker XWinNMR software - typed vconv command and there was an error that sound...
Posted: Evgeny Fadeev 5771 Aug 13 '10 at 13:33

Is it possible to keep increment time as zero in 2D?

2 0 4k
answers votes views
hi,i want to run NOESYPHPR with increment time as zero (d0=0).If possible, which software is easy to stack plot(in 1D-fo...
Posted: saship21 21 / Updated: Evgeny Fadeev 5771 Nov 11 '10 at 20:35

optimising o1 in solid state nmr

1 0 5k
answers votes views
I'm a little bit confused about setting o1, in the case of a solid sample First o1 is the offset of the transmitter fre...
Updated: silvernmr 11 Mar 09 '11 at 06:17

Low resolution of pepitde samples

3 0 4k
answers votes views
Dear friends, I am now trying to record the NOESY spectrum of my 30 amino acids peptide on DRX600 with a TXI cryo probe...
Posted: Yun Wang 1 / Updated: Evgeny Fadeev 5771 Jun 07 '11 at 14:00
75

questions tagged

bruker

Questions are sorted by the number of votes. Most voted questions are shown first.

Tags

× 75
× 34
× 25
× 15
× 13
× 11
× 11
× 10
× 10
× 10
× 9
× 7
× 6
× 3
× 3
× 3
× 1
× 1
× 1
× 1
× 1
posts per page103050

powered by CNPROG