Hi,
I wanna Brukers TopSpin/XWIN-NMR to log the start and end
times of every experiment.
With this information I can ...
oxy
31
Aug 28 '19 at 01:42
0 |
0 |
4k |
answers |
votes |
views |
Hi there,
I am looking for the pulse program for the PENDANT experiment, for a Bruker Avance III spectrometer, has anyon...
0 |
0 |
11406 |
answers |
votes |
views |
Hello everyone,
I had to change a BVT3300 module in a Bruker Avance 300 console today. Everytihing went fine and the mo...
0 |
0 |
8k |
answers |
votes |
views |
Hi,All,
I wonder if somebody can tell me why in these two experiments( also hbha(co)nh,I think) in Bruker(not sure if yo...
blue
1
Feb 28 '17 at 08:37
2 |
0 |
3k |
answers |
votes |
views |
We have been trying to get a 2D H-F experiment to work using the X 100 W amplifier on our Bruker NMR, but can't get it t...
0 |
0 |
9k |
answers |
votes |
views |
Hi all,
My question is about the Multiple Display (.md) function on TopSpin (Bruker AVIII).
I did some 'popt' ( paramete...
0 |
0 |
1k |
answers |
votes |
views |
I am running Paravision 4.0 from Topsin 1.5 with one receiver coil. I would like to increase the PPI acceleration factor...
adam
1
Jul 21 '15 at 05:18
2 |
0 |
7k |
answers |
votes |
views |
Hi ,
is there a way of predicting aquisition time needed depending on sample concentration in order to get a decent spe...
1 |
0 |
5k |
answers |
votes |
views |
Hi, I'm having a problem with topshim on Bruker AV 500 using topspin 2.1. it finishes with error (topshim: FieldMap - no...
2 |
0 |
9k |
answers |
votes |
views |
HELLO all nmr wikier,I am facing problem in runing topshim on bruker 500Mhz using topspin 2.1 it finishes with error (fi...
1 |
0 |
6k |
answers |
votes |
views |
Hello,
I was wondering if there was a waterLOGSY sequence among the bruker sequences. If not, could someone tell me whe...
1 |
0 |
3k |
answers |
votes |
views |
Hi all,
I'm having trouble reading the 2dseq file for a scan I ran. It should contain 2 slices of 66x50 voxels, repeate...
5 |
0 |
7k |
answers |
votes |
views |
Hello people,
Does anyone know of any free NMR software (no trials, I can't stand it anymore) that is robust enough to ...
Craig
41
Mar 05 '15 at 01:45
1 |
0 |
3k |
answers |
votes |
views |
Hi , Does any one know how to set up the zgesfpgp 1d experiment (flipback water gate) on Bruker. I am looking for p29 du...
0 |
0 |
1k |
answers |
votes |
views |
Hello people,
It's all in the title.
...
3 |
0 |
13683 |
answers |
votes |
views |
Hi,
I was wondering why so many pulse programs use dummy scans. Correct me if I'm wrong but I think dummy scans are supp...
2 |
0 |
5k |
answers |
votes |
views |
Hi,
I am trying to run a wet sequence but I'm having trouble getting good results on a sample with 90:10 water:methanol...
4 |
1 |
25479 |
answers |
votes |
views |
Hi and thanks for answering my prev. questions! Decided to ask this one:
How can I convert fid data (ser file) to plain...
3 |
0 |
7k |
answers |
votes |
views |
Hi all, I have been running TopSpin 2.1 on my Windows 7 32-bit OS for the last few years and now am getting this annoyin...
1 |
0 |
3k |
answers |
votes |
views |
hi there.
I want to establish an au with the following content:
I want to measure 1H and 31P make ssleep (userdefined)...
5 |
0 |
9k |
answers |
votes |
views |
Hello, could you tell me which HSQC and E-HSQC program are recommendable ?
These are Bruker HSQC pulse programs:
hsqcp...
RuudA
11
Sep 10 '14 at 11:46
4 |
0 |
25352 |
answers |
votes |
views |
Greetings,
I want to ask for some advice in matter of 15N hard pulse calibration on Bruker machines.
I'm working on Avan...
1 |
0 |
8k |
answers |
votes |
views |
Hello all,
I have several 2D and 3D data sets acquired using Bruker spectrometers in the standard uniform sampling fash...
5 |
0 |
17030 |
answers |
votes |
views |
Hello, I would like to find detailed technical info on the binary data storage formats for Varian and Bruker. Could anyo...
2 |
1 |
14587 |
answers |
votes |
views |
Hi All,
This may be a daft question, but how do I go about identifying the probe in our NMR machine, and hence whether ...
1 |
0 |
5k |
answers |
votes |
views |
Greetings,
I've some annoying issue with Topspin and deconvolution. No matter what I'm trying to do, border peaks are a...
3 |
0 |
7k |
answers |
votes |
views |
Greetings,
this is my first question in this wiki :)
I wonder if there's possibility to obtain full homo decoupled spe...
7 |
2 |
10799 |
answers |
votes |
views |
Hello,
Here are Bruker hmbc pulse programs (produced by ls *hmbc*):
hmbcacbigpl2ndqf hmbcacgplpqf hmbcetgpl2nd hm...
2 |
1 |
6k |
answers |
votes |
views |
Hello nmr wikier I want to run pulprog h2bcetgpl3 on bruker instrument using adiabiatic shape pulse crp60comp.4 I determ...
0 |
0 |
4k |
answers |
votes |
views |
Hello,
I can't get results, as unknown error occures data/results.csv